CE
CE Mark is the combination of Safety and EMC (Electro Magnetic Compatibility) and can not put the CE mark only for the safety approval or for the EMI approval, it has to be the combination of both.
There are more than one standards involved in order to get the CE approval.
Below you will see the standards names and their functions
CE approval standards names and their functions | Countries applicable to |
---|---|
CE with EN 60950 | All European countries |
CE with EN 50082-1 | All European countries |
CE with EN 55022 | All European countries |
CE with EN 61000-3-2 (IEC 555-2) | All European countries |
CE with EN 61000-3-3 (IEC 555-3) | All European countries |
CE with EN 61000-4-2 (IEC 801-2) | All European countries |
CE with EN 61000-4-3 (IEC 801-3) | All European countries |
CE with EN 61000-4-4 (IEC 801-4) | All European countries |
CE with EN 61000-4-5 (IEC 801-5) | All European countries |
CE with EN 61000-4-6 (IEC 801-6) | All European countries |
CE with EN 610004-8 (IEC 801-8) | All European countries |
CE with EN 61000-4-11 (IEC 801-11) | All European countries |
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Safety |
VERSIONS STANDARDS | EN-60950 & IEC 60950 Self Declaration |
MARKING | On the declaration of Conformity EN 60950 should be marked |
Top of page |
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | EMC: Generic immunity standard part 1 for residential, commercial & light industry. |
VERSIONS STANDARDS | EN-50082-1 Self Declaration |
MARKING | EN-50082-1 should be put on Declaration of Conformity |
Top of page |
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | EMC: Limits and methods of measurement of radio disturbance charistics of I.T.E. equipment. |
VERSIONS STANDARDS | EN-55022 Self Declaration |
MARKING | EN-55002 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-3-2 (IEC 555-2)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | EMC: Part 3; Sec. 2: Limits for harmonic Current emissions |
VERSIONS STANDARDS | EN-61000-3-2 Self Declaration |
MARKING | EN-61000-3-2 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-3-3 (IEC 555-3)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | EMC: Part 3; Sec. 3: Limits of voltage fluctions and flickers in low voltage supply system. |
VERSIONS STANDARDS | EN-61000-3-3 Self Declaration |
MARKING | EN-61000-3-3 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-4-2 (IEC 801-2)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Electrostatic Discharge (ESD) |
VERSIONS STANDARDS | EN-61000-4-2 Self Declaration Class B |
MARKING | EN-61000-4-2 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-4-3 (IEC 801-3)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Radiated RF. 3V/meter at 80MHz to 1GHz. |
VERSIONS STANDARDS | EN-61000-4-3 Self Declaration Class a |
MARKING | EN-61000-4-3 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-4-4 (IEC 801-4)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Electrical fast transient |
VERSIONS STANDARDS | EN-61000-4-4 Self Declaration Class B |
MARKING | EN-61000-4-4 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-4-5 (IEC 801-5)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Lightening and Burst. 2KV line to earth. 1KV line to line |
VERSIONS STANDARDS | EN-61000-4-5 Self Declaration Class B |
MARKING | EN-61000-4-5 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-4-6 (IEC 801-6)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Conducted RF. 1KV line to line |
VERSIONS STANDARDS | EN-61000-4-6 Self Declaration Class a |
MARKING | EN-61000-4-6 should be put on Declaration of Conformity |
Top of page |
CE with EN 610004-8 (IEC 801-8)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Power frequency Magnetic field at 50Hz |
VERSIONS STANDARDS | EN-61000-6-8 Self Declaration Class a |
MARKING | EN-61000-4-8 should be put on Declaration of Conformity |
Top of page |
CE with EN 61000-4-11 (IEC 801-11)
COUNTRIES APPLICABLE TO | All European countries |
ORIGINATING COUNTRY( S) | European Union |
WHAT IS MEASURED OR PERTAINED TO | Power frequency Magnetic field at 50Hz |
VERSIONS STANDARDS | EN-61000-4-11 Self Declaration Class a |
MARKING | EN-61000-4-11 should be put on Declaration of Conformity |
Top of page |